Customization: | Available |
---|---|
Certification: | VDE, CCC, ISO9001 |
Shell Material: | Aluminum Alloy |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Low-voltage Withdrawable Switchgear is a combined type cabinet assembled from standard modules by the factory, is applicable for power systems of AC50~60Hz, rated operating voltage up to and including 660V in power plants, transformer substations, petrochemical engineering, metallurgy, steel rolling, transportation energy, light industry, textile and other industrial enterprises and residential areas, high-rise buildings and so on, used for electric energy conversion, distribution and control. It complies with the standards GB7251 Low-voltage switchgear assembly, JB/T9961 Low-voltage withdrawable switchgear assembly, and the international standards IEC60439 GB7251.1.
Service conditions
High/Low voltage switchgear quality control:
The manufacturing of high/low voltage switchgear needs to be carried out in strict accordance with national standards, and quality control is required.
In manufacture in the process, materials, components, assembly, welding, insulation treatment, electrical testing and commissioning are required quality control.
At the same time, it is also necessary to carry out inspection, testing and acceptance.
HXGN -12 High Voltage Switchgear | ||
Item | Unit | Data |
Rated Voltage | kv | 12 |
Rated Frequency | Hz | 50 |
Rated Current of Main Busbar/Maximum Rated Current of Fuse | A | 630,125 |
Rated Short-time Withstands Current of Main Loop and Grounding Loop | KA/s | 20, 3 |
Rated Peak Withstand Current of Main Loop and Grounding Loop | KA | 50 |
Rated Shot-circuit Closing Current of Main Loop and Grounding Loop | KA | 50 |
Breaking Times of Load switch with Full Capacity | times | 100 |
Fuse Breaking Current | kA | 31.5, 40 |
Rated Closed Loop Breaking Current | A | 630 |
Rated Transfer Current | A | 1600 |
Mechanical Life | times | 2000 |
1min Power Frequency Voltage (Peak Value) (Phase to phase and Phase to Earth/Isolating Fracture | kv | 42, 48 |
Lightning Impluse Withstand Voltage (Peak Value) (Phase to phase and Phase to Earth/Isolating Fracture | kv | 75,85 |
1min Power Frequency Voltage of Secondary Loop | kv | 2 |
Protection Degree |
GGD AC Low Voltage Switchgear | ||||||
Type | Rated voltage(V) | Rated current(A) |
Rated short-circuit breaking current(kA) |
rated short time current(1s)(kA) |
Rated peak withstand current(kA) |
|
GGD1 | 380 | A | 1000 | 15 | 15 | 30 |
B | 600(630) | |||||
C | 400 | |||||
GGD2 | A | 1500(1600) | 30 | 30 | 63 | |
B | 1000 | |||||
C | 600 | |||||
GGD3 | A | 3150 | 50 | 50 | 105 | |
B | 2500 | |||||
C | 2000 |
GGJ Low Voltage Switchgear | |
Rated voltage | 0.38-0.66KV |
Rated frequency | 50HZ |
Rated capacity | 1-600Kvar |
Applicable voltage range | (0.85-1.1) times rated voltage |
maximum permissible current | 1.3 times rated current |
Control loop | Loop 1-16 |
Switching time | 1-150S/times |
Working mode | Automatic, continuous operation |
ATS Low Voltage Switchgear | |||
Item | Unit | Data | |
Rated voltage of main circuit |
V | AC380 | |
Rated voltage of auxiliary circuit |
V | AC220,AC380 | |
Rated frequency | HZ | 50 | |
Nominal insulation voltage | V | 660 | |
Rated current | A | ≤800 |
GCS Low Voltage Switchgear | |||
Item | Unit | Data | |
Rated voltage of main circuit |
V | 380/400/660 | |
Rated voltage of auxiliary circuit |
V | 220/380(400) 110/220 | |
Rated frequency | HZ | 50(60) | |
Nominal insulation voltage | V | 660(1000) | |
Rated current | A | ≤4000,1000 | |
generation line | A,B,C,PEN/A,B,C,PE,N | ||
Power frequency test voltage |
V | 2500/1760 | |
level of protection | IP30/IP40 |
MNS Low Voltage Switchgear | |||
Rated frequency(Hz) | 50/60 | ||
Rated voltage of auxiliary circuit(V) | 380,660 | DC110/220 | |
Nominal insulation voltage(V) | 660/1000 | ||
Rated operational current(A) | Horizontal bus-bar | ≤4000 | |
Vertical bus-bar(MCC) | 1000 | ||
Bus-bar | Three-phase four-wire system | A.B.C PEN | |
Three-phase five-wire system | A.B.C.PE.N | ||
Power frequency test voltage(V/1min) | Main circuit | 2500 | |
Auxiliary circuit | 1760 | ||
Rated voltage of main circuit(V) | AC 380/400/660 | ||
Rated short-time withstand current of bus-bar(kA/1s) | 10 | ||
Rated peak withstand current of bus-bar(kA/0.1s) | 105,176 | ||
Protect level | IP40, IP30 |
Kyn61-40.5 Armored Type Movable AC Metal-Enclosed Switchgear | ||
Item | Unit | Data |
Rated voltage | kV | 36kV, 40.5kV |
Rated frequency | Hz | 50/60 |
Rated current | A | 630, 1250, 1600, 2000, 2500, 3150, 4000 |
Branch busbar rated current | A | 630, 1250, 1600, 2000, 2500, 3150, 4000 |
Main busbar rated current | A | 630, 1250, 1600, 2000, 2500, 3150, 4000 |
1 min power frequency withstand voltage(wet/dry) | kV | 70/95 |
Lightning impulse withstand voltage | kV | 170/185 |
Rated short circuit breaking current(peak) | kA | 20/25/31.5/40 |
Short time withstand current(4s) | kA | 40/50/63/100 |
Protection type | IP4X for housing |
Kyn28A-12 Indoor withdrawout Metal-Clad and Metel-Closed Switchgear | ||
Item | Unit | Data |
Rated Voltage | kV | 3.6,7.2,12 |
Rated Frequency | Hz | 50 |
Rated Current of Circuit Breaker | A | 630,1250,1600,2000,2500,3150 |
Rated Voltage of Switchgear | A | 630,1250,1600,2000,2500,3150 |
Rated short-time withstand current (4s) | kA | 16,20,25,31.5,40,50 |
Rated Peak Withstand Current (Peak Value) | kA | 40,50,63,80,100,125 |
Rated Short-circuit Breaking Current | kA | 16,20,25,31.5,40,50 |
Rated Short- circuit Closing Current | kA | 40,50,63,80,100,125 |
1min Power Frequency Withstands Voltage | kV | 24, 32, 42 |
Lightning Withstands Voltage , Rated Insulation Leve | kV | 40, 60, 75 |
Protection Grade | Shell is IP4X, Shell is IP2X when compartment and circuit breaker doors are open |