Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer

Product Details
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio
Phase: Three
Core: Core-type Transformer
Still deciding? Get samples of US$ 100/Piece
Request Sample
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (9)
  • Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer
  • Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer
  • Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer
  • Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer
  • Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer
  • Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer
Find Similar Products

Basic Info.

Model NO.
5000kva
Cooling Method
Dry-type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001-2000, ISO9001, CCC
Usage
Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics
High Frequency
Shape of Core
U
Brand
LC
Type
Power, Electric, Distribution Transformer
Name
Dry Type Transformer
Phase Number
There Phase Transformer
Core Materials
Silicon Steel
Winding Material
Copper/Aluminium Winding
Vector Group
Dyn11 or Yyn0 (Customized)
Insulation Class
H-Class
Use
Power Transformer, Distribution Transformer
Insulation Material
Cast Resin
Accessories
Cooling Fans, Enclosure ,Temperature Control
Frequency
50Hz or 60Hz High Frequency Transformer
Transformer Type
Cast Resin Dry Type Rectifier Transformer
Category
Electric Power Transformer /Isolation Transformer
Types
Factory
Other Name
Voltage Transformer
Transport Package
Wooden Case Packing, Container Shipping
Specification
5000kva
Trademark
LC
Origin
China
HS Code
8504349000
Production Capacity
500PCS/Month

Product Description

Product Detail

1. Product Display

Our SC(B) series epoxy resin cast dry transformer is cast under vacuum with thin insulating bands automatically.
The core is made of a high-permeable grain-orientated silicon sheet and cast with imported epoxy resin.
The coil is reinforced with glass fiber and cast under vacuum with filler epoxy resin.
It has good mechanical properties, is free of crack and inner bubble, and has a low local discharge, high reliability and long service life.
The high and low-voltage systems are cast under vacuum, thus the coil will not absorb moisture, the clamps of the core are subjected to corrosion-resistant treatment and it may run under high temperature or other serious environments.
Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer
Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer

2. Product Drawing

 

Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer
3. Product Specification

 

SCB12/13/14/18 10KV/0.4KV 100kVA-3150kVA

              High Voltage:10(6,6.3,10.5,11)KV                               Connection Symbol:D,yn11 or Y,yn0                           Rated Frequency:50Hz/60Hz
              Low Voltage:0.4(0.415,0.433)KV                                   Tapping Range of HV:±2x2.5%                                 Insulation Level:LI75 AC35/AC3
Rated power
(KVA)
Short-Circuit Impedance(%) SC(B)18 (W) SC(B)14 (W) SC(B)12/13 (W) No-Load Current
(%)
Sound
pressure
dB(A)
Weight
(kg)
Inner Dimension(mm) Overall Dimension(mm)
No-Load Loss On-Load Loss75ºC No-Load Loss On-Load Loss75ºC No-Load Loss On-Load Loss75ºC L W H L W H
100 4 210 1120 245 1120 290 1240 1.5 45 590 1070 600 1160 1500 1100 2200
125 245 1320 290 1320 340 1460 1.3 46 740 1100 600 1200 1500 1100 2200
160 280 1510 330 1510 390 1680 1.3 46 810 1130 680 1240 1500 1100 2200
200 330 1800 380 1800 450 2000 1.1 46 890 1160 720 1250 1500 1100 2200
250 380 1960 445 1960 525 2180 1.1 46 1050 1220 720 1300 1500 1100 2200
315 465 2470 545 2470 640 2740 1.0 46 1250 1240 760 1260 1700 1300 2200
400 520 2840 605 2840 715 3150 1.0 46 1420 1260 830 1240 1700 1300 2200
500 610 3470 720 3470 845 3860 1.0 46 1530 1280 870 1200 1700 1350 2200
630 705 4180 830 4180 975 4650 0.9 48 1810 1330 880 1230 1700 1350 2200
630 6 680 4240 805 4240 945 4710 0.9 48 1760 1470 880 1180 1700 1350 2200
800 795 4950 940 4950 1105 5500 0.9 48 2090 1500 900 1130 1900 1350 2200
1000 930 5780 1095 5780 1290 6430 0.8 48 2500 1570 900 1220 1900 1350 2200
1250 1095 6890 1290 6890 1520 7660 0.8 48 2920 1610 900 1330 2100 1500 2200
1600 1290 8350 1515 8350 1780 9270 0.8 48 3650 1720 900 1420 2100 1500 2200
2000 1600 10280 1890 10280 2220 11420 0.7 50 4190 1780 980 1480 2300 1500 2200
2500 1890 12210 2230 12210 2620 13570 0.7 50 5400 2000 1020 1830 2300 1600 2200
3150 2340 14640 2695 14640 3100 16150 0.5 50 6730 2030 1270 2050 2350 1600 2200
Note: The above parameters are only for designing and selecting  reference, and the final parameters are subject to the actual product.

SCB12/13/14/18 20KV/0.4KV 200kVA-3150kVA
                High Voltage::20(15,22,24)KV                                    Connection Symbol:D,yn11 or Y,yn0                                      Rated Frequency:50Hz/60Hz
                Low Voltage:0.4(0.415,0.433)KV                                  Tapping Range of HV:±2x2.5%                                           Insulation Level:LI125 AC55/AC3
Rated power
(KVA)
Short-Circuit Impedance(%) SC(B)18 (W) SC(B)14 (W) SC(B)12/13 (W) No-Load Current
(%)
Sound
pressure
dB(A)
Weight
(kg)
Inner Dimension(mm) Overall Dimension(mm)
No-Load Loss On-Load Loss75ºC No-Load Loss On-Load Loss75ºC No-Load Loss On-Load Loss75ºC L W H L W H
200 6 390 2090 450 2090 530 2320 1.5 46 1250 1460 720 1350 1900 1350 2200
250 440 2430 520 2430 610 2700 1.3 46 1480 1490 720 1430 1900 1350 2200
315 510 2900 600 2900 710 3220 1.3 47 1550 1510 720 1470 2100 1400 2200
400 610 3450 710 3450 840 3820 1.1 48 1730 1550 720 1500 2100 1400 2200
500 710 4120 840 4120 980 4580 1.1 48 1980 1580 830 1550 2100 1400 2200
630 800 4870 950 4870 1110 5410 1.0 49 2280 1600 830 1600 2100 1500 2200
800 920 5870 1080 5870 1270 6530 1.0 50 3180 1730 830 1760 2300 1500 2200
1000 1080 6950 1280 6950 1500 7730 0.8 50 3580 1800 830 1780 2300 1500 2200
1250 1250 8180 1470 8180 1730 9090 0.8 52 3680 1820 900 1850 2400 1500 2200
1600 1460 9820 1720 9820 2030 10910 0.8 52 4680 1980 920 2040 2500 1600 2200
2000 1700 11600 2010 11600 2360 12880 0.7 53 5340 2200 960 2080 2700 1600 2200
2500 8 2030 13720 2400 13720 2810 15250 0.7 53 6480 2330 990 2170 2800 1700 2200
3150 2510 16330 2840 16330 3320 18150 0.6 54 7530 2360 1270 2250 2800 1700 2200
Note: The above parameters are only for designing and selecting  reference, and the final parameters are subject to the actual product.

SCB12/13/14/18 35KV/0.4KV 200kVA-3150kVA
              High Voltage: 35(33,38.5)KV                                 Connection Symbol:D,yn11 or Y,yn0                           Rated Frequency:50Hz/60Hz
              Low Voltage: 0.4(0.415,0.433)KV                         Tapping Range of HV:±2x2.5%                                   Insulation Level: LI200 AC85/AC3
Rated power
(KVA)
Short-Circuit Impedance(%) SC(B)18 (W) SC(B)14 (W) SC(B)12/13 (W) No-Load Current
(%)
Sound
pressure
dB(A)
Weight
(kg)
Inner Dimension(mm) Overall Dimension(mm)
No-Load Loss On-Load Loss75ºC No-Load Loss On-Load Loss75ºC No-Load Loss On-Load Loss75ºC L W H L W H
200 6 470 2360 540 2360 640 2630 1.5 51 1550 1590 920 1790 2300 1600 2200
250 520 2700 610 2700 720 3010 1.3 51 1750 1590 920 1860 2300 1600 2200
315 620 3210 730 3210 850 3570 1.3 51 1950 1650 850 1750 2400 1700 2200
400 730 3850 850 3850 1000 4280 1.1 51 2200 1840 890 1800 2400 1700 2300
500 850 4730 1010 4730 1180 5260 1.1 52 2640 1910 920 1800 2500 1700 2300
630 970 5480 1150 5480 1350 6090 1.0 52 2880 1970 930 2100 2600 1700 2400
800 1130 5830 1340 5830 1570 6480 1.0 52 3530 1980 1030 2030 2600 1800 2500
1000 1280 7400 1510 7400 1760 8230 0.8 52 4080 2070 1060 2070 2700 1800 2500
1250 1480 9040 1750 9040 2060 10040 0.8 53 4430 2080 1050 2080 2700 1800 2500
1600 1710 10960 2010 10960 2360 12180 0.8 53 5310 2150 1050 2180 2800 1800 2600
2000 2010 12960 2370 12960 2780 14390 0.7 54 6410 2300 1050 2250 2900 1800 2700
2500 8 2340 15500 2760 15500 3240 17230 0.7 55 7630 2400 1100 2230 3000 2000 2700
3150 2890 18590 3330 18590 3830 20510 0.6 55 7530 2500 1200 2350 3000 2000 2800
Note: The above parameters are only for designing and selecting  reference, and the final parameters are subject to the actual product.

4. Product Structure
Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer

Product Process

Scb Three Phase 5000kVA 35kv Cast Resin Dry Type TransformerScb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer

Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer       Raw Materials                             Core Slitting                              Core Cutting
Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer
       Core Stacking                              Insulating Curing                     HV Winding
Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer        LV Winding                                  Pouring                                     Drying
Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer        Assembly                                     Testing                                         Warehouse

Product Application

Dry-type transformers are widely used in various industries and applications that require high safety, reliability, and environmental compatibility. Some of the common applications of dry-type transformers are:
1 Chemical, oil, and gas industry: Dry-type transformers are used to supply power to various equipment and processes that involve flammable or explosive substances, such as refineries, petrochemical plants, pipelines, offshore platforms, etc.
2 Environmentally sensitive areas: Dry-type transformers are used to protect the environment from oil spills or leaks that can contaminate water sources, soil, or wildlife habitats, such as water protection areas, forests, wetlands, etc.
3 Fire-risk areas: Dry-type transformers are used to prevent fire hazards or minimize fire damage in areas that are prone to fire outbreaks or have strict fire regulations, such as indoor substations, underground substations, hospitals, schools, hotels, shopping malls, etc.
4 Renewable generation: Dry-type transformers are used to connect renewable energy sources to the grid or to the load, such as wind turbines, solar panels, hydroelectric plants, etc.
5 Other applications: Dry-type transformers are also used in other applications that require high performance, low maintenance, or special features, such as traction systems, marine systems, mining systems, data centers, etc.

Related Products
Scb Three Phase 5000kVA 35kv Cast Resin Dry Type TransformerCompany Profile

HeBei LeiCheng Since its inception, always adhere to the "quality first, credit first" business purpose, constantly develop innovative products, expand the market, and with many scientific research units, colleges and universities work closely and hired professional and technical personnel as guideline, USES the domestic and foreign advanced technology, experienced several years of hard struggle, finally achieved gratifying results, specifically Industry production of single-phase three-phase conversion power supply, control transformer, three coherent transformer, CNC machine tool control transformer, main transformers, power transformers, power transformers, special transformers, voltage regulator, voltage regulator, reactor, inverter, soft start and other CNC machine tools widely used, the company pays attention to the development of products, research and development at the same time, constantly strengthen the quality management.

Office Environment

Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer
Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer
Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer
Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer
Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer
Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer

Factory

Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer

Certifications

Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer
Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer
Scb Three Phase 5000kVA 35kv Cast Resin Dry Type Transformer


Scb Three Phase 5000kVA 35kv Cast Resin Dry Type TransformerFAQ

1. Who we are ?
We are based in HeBei, China,sell to Domestic Market(80.00%),Southeast Asia(20.00%). There are all about 1200-1500 people in our company.

2.How can we guarantee quality?
 Always make a final Inspection before shipping.

 
3.What can you buy from us?
110kV-220kV Oil-immersed Power Transformer,Dry-type Transformer,Unpacked H Grade Dry Transformer,Oil-immersed Distribution Transformer, Pad-mounted Transformer,Enameled Wire,Composite Wire,Transposed Wire,Paper Covered Wire,Film Wrapped Wire.

 
4.Why should you buy from us not from other suppliers?
As an enterprise specializing in transformer production, we have high quality, fast delivery, guarantee after-sales service and factory price. What's more, we have ISO9001-2008, OHSAS 18001:2007, ISO4001:2004L ,UL ,CE certificates and IEC, ANSI, KEMA, GOST standard.

 
5.What services can we provide?
Accepted Delivery Terms: FOB,CIF,EXW; Accepted Payment Currency:USD,CNY; Accepted Payment Type: T/T,L/C; Language Spoken:English,Chinese.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier