Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet

Product Details
Customization: Available
Certification: VDE, CCC, ISO9001
Shell Material: Aluminum Alloy
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (9)
  • Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet
  • Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet
  • Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet
  • Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet
  • Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet
  • Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet
Find Similar Products

Basic Info.

Model NO.
Low Voltage Switchgear
Voltage Level
Low Voltage
Installation
Fixed
Structure
Cabinet
Current
AC
Product Name
Electrical/Power/Distribution Cabinet Switchg
Full Title
Electrical High/Medium/Low Voltage Switchgear
Classify
Metal Clad/Ring Main Unit Switchgear
Type
AC Metal Enclosed/ Compact/Gis/ Gas Switchgear
Use
Power Distribution/Substation Switchgear
Other Name
Distribution Box/Panel Board Switchgear
Classification
Device/Model / Voltage Draw out Switchgear
Another Name
Voltage Metal Clad / Enclosed Switchgear
Form
Hv/ Mv/ LV Switchgear
Way to Install
Enclosed Ring Network Switch Cabinet Switchgear
Shell Type
Metal Clad Removable Switchgear
Installation Site
Outdoor / Indoor Switchgear
Advantage
Looped Network AC/Rmu Switchgear
Useful
Power Transmission/Electric Switchgear
Useful2
Power Distribution Equipment Switchgear
Transport Package
Wooden Case
Specification
AC: 380V/400V/660V
Trademark
leicheng
Origin
China
HS Code
8537209000
Production Capacity
60 Pieces/Week

Product Description

Product Detail
Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet
High/Low voltage switchgear refers to the electrical products used for power system generation, transmission, distribution, power conversion and consumption to play the role of on-off, control or protection, voltage level in 3.6kV~550kV, mainly including high/low voltage isolation switch and ground switch, high voltage load switch, high voltage automatic recirculation and sectioner. High voltage operating mechanism, high/low voltage explosion-proof distribution device and high voltage switchgear and other categories.
The switchgear has the functions of overhead inlet and outlet line, cable inlet and outlet line, and busbar connection. It is mainly used in power plants, substations, petrochemical industry, metallurgical steel rolling, light textile industry, factories and mining enterprises, residential areas, high-rise buildings and other different places.

The high and low voltage switchgear is an important part of the power system, which is mainly used to break the circuit, protect the power equipment and control the power system. The following is the main role of high and low voltage switchgear:

1. Disconnect the circuit

The high and low voltage switchgear can successfully perform the switching operation of the circuit breaker, that is, the switchgear can separate or connect the power supply by controlling the switch, and ensure the continuity of power transmission while maintaining the safety of the circuit and equipment.

2. Protect power devices

In the power system, the transmission process of high-voltage power supply will produce various faults, such as overload, short circuit and ground fault. The high voltage switchgear can choose the appropriate protection device according to the actual situation, detect and deal with these faults in time, and ensure the normal operation of the power equipment.

3. Control the power system

The high and low voltage switchgear can control the switch and state of the power equipment according to the actual needs of the power system. For example, when controlling the power system in real time, it is necessary to precisely adjust the transmission and distribution of power, and the high and low voltage switchgear can achieve this by controlling the switch.
Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet
High/Low voltage switchgear is usually composed of switchgear, meters, control appliances, insulating parts, connecting parts, mechanisms, enclosures and bases. Switchgear is the core component of high voltage switchgear, it is to achieve high voltage line switching, disconnecting and load switching equipment, according to different uses can be divided into circuit breakers, load switches, combined electrical appliances, grounding switches and so on. Instrument is used to display the operating status of the switch cabinet equipment, such as ammeter, voltmeter, indicator light, etc. Control appliances are devices used to control the operation of the switch cabinet, such as control buttons, relays, remote controls, etc. Insulation parts are used to isolate the parts between electrical equipment, such as insulation board, insulation column, etc. Connecting parts are used to connect electrical equipment between the parts, such as conductive strips, patch panels, etc. A mechanism is a component used to realize the action of a switching device, such as a manual mechanism, an electric mechanism, etc. The shell is used to protect the parts of the equipment inside the switch cabinet, such as the steel plate shell, protective cover, etc. The base is used to support the switch cabinet components, such as steel plate base, Angle iron base, etc.
 

The main materials used are as follows:

1.Cold-rolled steel or Angle steel (for welding cabinets);

2.Aluminum coated zinc steel or galvanized steel (for assembly cabinets).

3.Stainless steel plate (non-magnetic).

4.Aluminum plate ((non-magnetic).

5.The functional unit of the cabinet

6.Main bus room (General main bus layout according to the "product" shape or "1" shape of two structures

7.Breaker room

8.Cable house

9.Relay and instrument room

10.Cabinet top small bus room

Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet
Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet
Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet

Product Parameters
High/Low voltage switchgear quality control:

The manufacturing of high/low voltage switchgear needs to be carried out in strict accordance with national standards, and quality control is required.
In manufacture in the process, materials, components, assembly, welding, insulation treatment, electrical testing and commissioning are required quality control.
At the same time, it is also necessary to carry out inspection, testing and acceptance.

HXGN  -12 High Voltage Switchgear
Item Unit Data
Rated Voltage kv 12
Rated Frequency Hz 50
Rated Current of Main Busbar/Maximum Rated Current of Fuse A 630,125
Rated Short-time Withstands Current of Main Loop and Grounding Loop KA/s 20, 3
Rated Peak Withstand Current of Main Loop and Grounding Loop KA 50
Rated Shot-circuit Closing Current of Main Loop and Grounding Loop KA 50
Breaking Times of Load switch with Full Capacity times 100
Fuse Breaking Current kA 31.5, 40
Rated Closed Loop Breaking Current A 630
Rated Transfer Current A 1600
Mechanical Life times 2000
1min Power Frequency Voltage (Peak Value) (Phase to phase and Phase to Earth/Isolating Fracture kv 42, 48
Lightning Impluse Withstand Voltage (Peak Value) (Phase to phase and Phase to Earth/Isolating Fracture kv 75,85
1min Power Frequency Voltage of Secondary Loop kv 2
Protection Degree    IP3X
GGD AC Low Voltage Switchgear
Type Rated voltage(V) Rated current(A)

Rated short-circuit breaking current(kA)

rated short time current(1s)(kA)

Rated peak withstand current(kA)

GGD1 380 A 1000 15 15 30
B 600(630)  
C 400
GGD2 A 1500(1600) 30 30 63
B 1000
C 600
GGD3 A 3150 50 50 105
B 2500
C 2000
GGJ Low Voltage Switchgear
Rated voltage 0.38-0.66KV
Rated frequency 50HZ
Rated capacity 1-600Kvar
Applicable voltage range (0.85-1.1) times rated voltage
maximum permissible current 1.3 times rated current
Control loop Loop 1-16
Switching time 1-150S/times
Working mode Automatic, continuous operation
ATS Low Voltage Switchgear 
Item Unit Data

Rated voltage of main circuit

V AC380

Rated voltage of auxiliary circuit

V AC220,AC380
Rated frequency HZ 50
Nominal insulation voltage V 660
Rated current A ≤800
GCS Low Voltage Switchgear 
Item Unit Data

Rated voltage of main circuit

V 380/400/660

Rated voltage of auxiliary circuit

V 220/380(400)   110/220
Rated frequency HZ 50(60)
Nominal insulation voltage V 660(1000)
Rated current A ≤4000,1000
generation line A,B,C,PEN/A,B,C,PE,N

Power frequency test voltage

V 2500/1760
level of protection IP30/IP40
MNS Low Voltage Switchgear
Rated frequency(Hz)   50/60
Rated voltage of auxiliary circuit(V)   380,660 DC110/220
Nominal insulation voltage(V)   660/1000
Rated operational current(A) Horizontal bus-bar ≤4000
Vertical     bus-bar(MCC) 1000
Bus-bar Three-phase four-wire system A.B.C  PEN
Three-phase five-wire system A.B.C.PE.N
Power frequency test voltage(V/1min) Main circuit 2500
Auxiliary circuit 1760
Rated voltage of main circuit(V)   AC 380/400/660
Rated short-time withstand current of bus-bar(kA/1s)   10
Rated peak withstand current of bus-bar(kA/0.1s)   105,176
Protect level   IP40, IP30
Kyn61-40.5 Armored Type Movable AC Metal-Enclosed Switchgear
Item Unit Data
Rated voltage kV 36kV, 40.5kV
Rated frequency Hz 50/60
Rated current A 630, 1250, 1600, 2000, 2500, 3150, 4000
   A 630, 1250, 1600, 2000, 2500, 3150, 4000
Main busbar rated current A 630, 1250, 1600, 2000, 2500, 3150, 4000
1 min power frequency withstand voltage(wet/dry) kV 70/95
Lightning impulse withstand voltage kV 170/185
Rated short circuit breaking current(peak) kA 20/25/31.5/40
Short time withstand current(4s) kA 40/50/63/100
Protection type   IP4X for housing

 

Kyn28A-12 Indoor withdrawout Metal-Clad and Metel-Closed Switchgear
Item Unit Data
Rated Voltage kV 3.6,7.2,12
Rated Frequency Hz 50
Rated Current of Circuit Breaker A 630,1250,1600,2000,2500,3150
Rated Voltage of Switchgear A 630,1250,1600,2000,2500,3150
Rated short-time withstand current (4s) kA 16,20,25,31.5,40,50
Rated Peak Withstand Current (Peak Value) kA 40,50,63,80,100,125
Rated Short-circuit Breaking Current kA 16,20,25,31.5,40,50
Rated Short- circuit Closing Current kA 40,50,63,80,100,125
1min Power Frequency Withstands Voltage kV 24, 32, 42
Lightning Withstands Voltage , Rated Insulation Leve kV 40, 60, 75
Protection Grade Shell is IP4X, Shell is IP2X when compartment and circuit breaker doors are open


Product productive process

High/Low voltage switchgear manufacturing process

1. Material preparation: The manufacture of high voltage switchgear requires a large number of metal materials, and it is necessary to prepare materials according to the requirements design drawings accurate cutting, bending, stamping and drilling.

 

2. Parts manufacturing: After obtaining qualified materials, it is necessary to manufacture parts. Parts manufacturing includes hardware manufacturing, sheet metal manufacturing, casting manufacturing and processing, etc.

 

3. Assembly: After parts manufacturing, assembly is required. The assembly needs to be grouped according to the design drawing to ensure that each component is installed in the correct position.
 


 

 

Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet

 

Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet

4. Welding: After the assembly is completed, the switch cabinet needs to be welded to ensure that the structure of the switch cabinet is firm.

5. Insulation treatment: After the welding is completed, the switch cabinet needs to be insulated to prevent electrical equipment between there is a leak.

6. Electrical test: After insulation treatment, electrical test is required. Electrical testing ensures it is on

The electrical performance of the closed cabinet meets the design requirements.

 

7. Trial run: After the electrical test is completed, it is necessary to conduct trial run. Different scenarios need to be simulated during trial operation the operating status of the switchgear to ensure the normal operation of the switchgear.

 

8. Packaging and transportation: After the completion of the trial operation, the switch cabinet needs to be packaged, transported and installed.

Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet


Product Application:

 

Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet
Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet


High and low voltage switchgear in the power system has a wide range of applications, the following are some common application scenarios:

1. Power transmission and transformation station

In large power transmission and transformation stations, a number of high-voltage switchgear will be set up as the main control device of the power system. These switchgear can protect and control the entire power transmission and transformation station, and can detect and deal with various faults.

2. Industrial and mining enterprises

In industrial and mining enterprises, high-voltage power equipment, such as transformers, generators and motors, is often needed. The high voltage switchgear can protect and control these devices to ensure that the equipment operates in normal working conditions.

3. Buildings

In some large buildings, it is necessary to use high and low voltage power equipment, such as air conditioning, elevators and lighting. The high and low voltage switchgear can control these devices to meet the actual needs of the building.

In short, high and low voltage switchgear plays an important role in the power system, they can be applied to a variety of scenarios, protect and control power equipment, to ensure the safe and stable operation of the power system.

Company Profile

HeBei LeiCheng Since its inception, always adhere to the "quality first, credit first" business purpose, constantly develop innovative products, expand the market, and with many scientific research units, colleges and universities work closely and hired professional and technical personnel as guideline, USES the domestic and foreign advanced technology, experienced several years of hard struggle, finally achieved gratifying results.
Specifically Industry production of All kinds of Transformer, Transformer Substation and accessories

(single-phase three-phase conversion power supply, control transformer, three coherent transformer, CNC machine tool control transformer, main transformers, power transformers, special transformers, voltage regulator, voltage regulator, reactor, inverter, soft start and other CNC machine tools widely used) Fastener, Electric power fittings, All kinds of Steel etc...
The company pays attention to the development of products, research and development at the same time, constantly strengthen the quality management.


Office Environment
Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet

Factory
Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet

Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet
Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet

Packaging&Shipping
Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet

 

Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet

 

Certifications

Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet
Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet
Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet


Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet

FAQ

1. Who we are ?
We are based in HeBei, China,sell to Domestic Market(80.00%),Southeast Asia(20.00%). There are all about 1200-1500 people in our company.

2.How can we guarantee quality?
 Always make a final Inspection before shipping.

 
3.What can you buy from us?
110kV-220kV Oil-immersed Power Transformer,Dry-type Transformer,Unpacked H Grade Dry Transformer,Oil-immersed Distribution Transformer, Pad-mounted Transformer,Enameled Wire,Composite Wire,Transposed Wire,Paper Covered Wire,Film Wrapped Wire.

 
4.Why should you buy from us not from other suppliers?
As an enterprise specializing in transformer production, we have high quality, fast delivery, guarantee after-sales service and factory price. What's more, we have ISO9001-2008, OHSAS 18001:2007, ISO4001:2004L ,UL ,CE certificates and IEC, ANSI, KEMA, GOST standard.

 
5.What services can we provide?
Accepted Delivery Terms: FOB,CIF,EXW; Accepted Payment Currency:USD,CNY; Accepted Payment Type: T/T,L/C; Language Spoken:English,Chinese.


Related Product

Our plants produce all types of transformers and related power equipment, including substations, capacitor cabinets, header cabinets, dry transformers and more. Related products can be found on our home page, or contact me directly, let me help you!

Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet
Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet
Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet
Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet
Electrical Cabinet Ring Main Unit AC Metal Enclosed Switchgear for Switch Cabinet
 

                                 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier